qiao@hvtest.cc15871365102
  • YDQ Aufblasbarer Typ AC Hipot Testtransformator Hochspannungs-Hipot-Testset

    Der 50-120-kV-SF6-Gastyp-Prüftransformator der YDQ-Serie besteht hauptsächlich aus: Steuerkasten, Prüftransformator usw. Er kann den Netzfrequenz-Wechselstrom-Gleichstrom-Spannungstest für Kabel, elektrische Komponenten, Isoliermaterial usw. durchführen.

    Produktdetails des aufblasbaren YDQ-Hochspannungs-Hipot-Testtransformator-Hochspannungs-Hipot-Testsatzes


    YDQ Gas Type AC/DC Hipot Test Set

    Product Introduction

    YDQ series AC Hipot Test Set are essential equipments during electrical equipments tests and preventive tests. With the development of China's power industry, people required higher about the voltage class of testing transformer, and the traditional oil / dry type test transformer cannot meet the requirement in volume, weight, and functions.

    With the development of Chinese basic scientific research, the appliance of new material and new workmanship, the new medium SF6 enter the electrical equipment applications. The SF6 widely used because of its excellent insulating properties and arc performance and incombustible.

    AC Hipot Test Set compared with the traditional oil / dry type test transformer, 20%-60% reduction in weight (depend on the voltage and capacity class), without oil pollution, voltage class can up to 300kV, less than 2Pc under rated voltage. It is especially suitable for condition of working or moving frequently.


    Product Characteristics
    1、The inflatable test transformer is compact in size and lightweight, weighing 40%–65% less than oil-immersed transformers of the same grade.
    2、It operates without oil or grease, requiring virtually no maintenance.
    3、The unit is resistant to adverse weather and environmental conditions, remains stable during field transport, and is ready for immediate testing on-site.

    4、It offers significantly higher insulation strength compared to oil-immersed transformers and produces minimal corona discharge.


    Product Parameter

    technische Parameter

    voltage classes10kV~300kV
    range of capacity1~500kVA
    no-load current<7%
    impedance voltage<8%
    product classificationinterflow、ac/dc、Ac cascade、Ac-dc cascade


    Main product specifications

    specifications and modelscapacity(kVA)High Voltage(kV)High tension current(mA)low input voltage converterbend-beam-rheometertemperature rise℃(30 minutes)
    voltage(V)electricity(A)
    YDQ-1,5/501.550302007.550010
    YDQ-3/50350602001550010
    YDQ-5/505501002002550010
    YDQ-10/5010502002005050010
    YDQ-20/5020504004005350010
    YDQ-30/5030506004007950010
    YDQ-50/50505010004001250010
    YDQ-5/10051005020025100010
    YDQ-10/1001010010020050100010
    YDQ-20/1002010020040053100010
    YDQ-30/1003010030040079100010
    YDQ-50/10050100500400132100010
    YDQ-20/1502015013340053150010
    YDQ-30/1503015020040080150010
    YDQ-50/15050150333400132150010
    YDQ-100/150100150667400263150010
    YDQ-50/20050200250400132200010
    YDQ-100/200100200500400263200010
    YDQ-150/200150200750400395200010
    YDQ-200/2002002001000400526200010
    YDQ-300/2003002001500400790200010
    YDQ-50/30050300170400132300010
    YDQ-100/300100300333400263300010
    YDQ-150/300150300500400395300010
    YDQ-200/300200300667400526300010
    YDQ-300/3003003001000400790300010


    Application Fields

    1. Power system. Mainly used for detection and preventive testing to ensure the normal operation of high-voltage power equipment.

    2. Subway and railway. High voltage testing is used for traction power supply systems and signal systems in subways and railways to ensure the reliability and safety of these critical systems.

    3. Industrial and mining enterprises. Regularly maintain and inspect various high-voltage electrical equipment in industrial and mining enterprises, and test the insulation strength of the equipment through high-voltage testing.

    4. Power plant. Used for high-voltage testing of generators, transformers, circuit breakers, and other equipment to ensure the stable operation of the power generation system.

    5. Petrochemical industry. Used for voltage withstand testing of high-voltage switchgear, cables, and insulation materials in the petrochemical industry to prevent safety accidents caused by high voltage.

    6. Postal and telecommunications. Used for high-voltage testing of communication base stations, transmission lines, and other equipment to ensure smooth communication.

    7. Research institutions. Conduct research and testing on various high-voltage electrical equipment to verify the performance of new technologies and materials.

    8. Military field. Used for testing high-voltage electrical systems in military equipment, including radar, communication, and control systems.

    9. Aerospace. Used for high-voltage testing of high-tech equipment such as satellites and rockets to ensure their safe launch and operation.


    HTY_1016

    Dienstleistungskonditionen
    1. Rated conditions requirements of AC testing transformer:
    A. Ambient temperature : maximum: +40 ℃ minimum:-20 ℃
    B. Maximum relative humidity, when the air temperature is 25 ℃, relative humidity less than 85%.
    C. Installation site without seriously affecting the transformer insulating gas, steam, chemical dust, dirt and other explosive media.
    D. AC test transformer the input voltage gradually increases and the output should be with sufficient protection resistor in series, should open/close under high voltage.
    2. Allowed running time
    Under rated voltage of rated capacity, continuous operation shall not exceed half an hour, every interval time is 5-10 times of working time, in order to ensure adequate cooling of the transformer, under rated voltage and two-thirds of the rated current allows long-term continuous operation


    Frequently Asked Questions

    1 . Can it be used in conjunction with a series resonant system?

    Okay. Inflatable test transformers can be an important component of AC withstand voltage systems, and can also be combined with series resonant devices, high-voltage dividers, control consoles, protective resistors, and other equipment to form a complete withstand voltage test system according to test requirements.

    2. Is it suitable for on-site testing?

    Yes, it is. Due to its lightweight, compact structure, and convenient transportation, the inflatable test transformer is highly suitable for mobile testing scenarios such as substations, power plants, construction sites, and equipment maintenance sites.

    3. Does SF₆ gas need to be replenished frequently?

    Under normal circumstances, frequent supplementation is not necessary. The equipment adopts a sealed structure, and the SF₆ gas leakage rate is extremely low. Confirm that the air pressure is normal during regular maintenance and inspection. If the air pressure drops after long-term use, supplement the gas according to the instructions.









    Das könnte Ihnen auch gefallen

    • Haben Sie Fragen!

      Zögern Sie nicht, uns jederzeit zu kontaktieren
      Kontaktiere uns
    • Besuchen Sie uns

      Gebäude 6, Optics Valley Optical-Mechanical Industrial Park, 84 Gaoxin 5 Road,
      East Lake New Technology Development Zone, Stadt Wuhan, Provinz Hubei, China

    • Schreiben Sie uns eine E-Mail

      qiao@hvtest.cc

    • Rufen Sie uns an

      +86-15871365102