qiao@hvtest.cc15871365102
  • UHV-801 Ground Network Earth Resistance Tester

    Ground Network Earth Resistance Tester revolutionizes earth grid resistance measurement in power systems by replacing traditional 30A power-frequency methods with frequency-conversion AC technology and microprocessor control.

    Product Details of UHV-801 Ground Network Earth Resistance Tester


    Product Introduction

    Wuhan UHV Power Technology Co.,Ltd., is a professional manufacturer and supplier of high-voltage power testing equipment in China.This UHV-801 Ground Network Earth Resistance Tester utilizes frequency-conversion technology and microprocessor control to accurately measure grounding resistance (4Ω-10Ω), contact/step voltage, and soil resistivity. Featuring 50Hz anti-interference capability and 3A test current, it enables reliable live-grid testing without power outages. The compact design significantly improves efficiency, reducing testing time and labor intensity compared to traditional 30A methods. Suitable for substations, power plants, and lightning protection systems.


    7360373605


    Key Features of Ground Grid Resistance Tester:

    1、Precision Power Frequency Simulation - Delivers accurate sinusoidal waveforms with ±5Hz frequency variation (45Hz/55Hz), ensuring power frequency equivalence in measurements.

    2、Advanced Anti-Interference Technology - Combines variable frequency measurement with digital filtering for stable, reliable data even in high-noise environments.

    3、Exceptional Accuracy - Achieves 0.005Ω basic error resolution, capable of testing low-impedance grounding systems with precision.

    4、Comprehensive Measurement Capabilities - Tests current/voltage poles, grounding resistance, step voltage, and contact voltage in one integrated solution.

    5、User-Friendly Interface - Features intuitive Chinese menu navigation with direct measurement readouts for simplified operation.

    6、Efficient Field Operation - Eliminates heavy cabling requirements with compact design that doesn't require high-current lines.


    Technical Advantages:

    • True power frequency simulation

    • Superior noise rejection

    • Micro-ohm resolution

    • Multi-parameter testing

    • Simplified workflow

    • Lightweight field deployment


    Technical parameter

    Messbereich0–200 Ω (einschließlich der aktuellen Pfahlimpedanz)
    Auflösung0,001 Ω
    Messfehler±(Messwerte×1 %+0,005 Ω)
    maximale AusgangsspannungAC 400 V (45 Hz, 55 Hz, Zweifrequenz, Sinuswelle)
    maximaler AusgangsstromAC 5A (45 Hz, 55 Hz, Zweifrequenz, Sinuswelle)
    Abtriebsrad5 / 4,5/4/3,5/3/2,5/2/1,5/1a, alle 0,5A, insgesamt 9 Gänge
    Anti-Interferenz-FähigkeitAnti-Power-Frequenz 50 Hz Spannung 10 V
    Anforderungen an MessleitungenQuerschnittsfläche des Kupferkerns des Stromdrahtes ≥ 1,5 mm2
    Querschnittsfläche des Kupferkerns der Spannungsleitung ≥ 1,0 mm2
    StromversorgungAC220V ± 10 %, 50 Hz
    Externe Dimension295×340×310mm3
    Instrumentengewicht30kg


    Application Scenarios

    Substation grounding grid testing
    Used for testing the ground resistance, touch voltage, and step voltage of large substation grounding grids, determining whether the grounding system meets requirements for safe operation.

    Power plant grounding system testing
    Used for grounding system testing of large power generation facilities such as thermal power plants and hydroelectric plants, ensuring that power generation equipment and plant grounding systems are reliable.

    Lightning protection grounding system testing
    Used for testing the grounding performance of lightning protection grounding systems for buildings, power facilities, and other structures, ensuring that lightning currents can be safely discharged.

    Large grounding grid safety performance testing
    Can perform comprehensive testing of ground resistance, touch voltage, and step voltage on large grounding grids, evaluating safety risks to personnel and equipment.

    Grounding grid construction, retrofitting, and acceptance testing
    Used for on-site acceptance testing after completion of new or retrofitted grounding grids, verifying whether the construction quality and grounding performance of the grounding system meet requirements.

    Soil resistivity testing and grounding system design
    By measuring soil resistivity, provides a basis for the design of grounding grids and the arrangement of grounding electrodes for substations, power plants, and other projects.


    Frequently Asked Questions

    Q:What can this Grounding Grid Tester measure?
    A:It can measure grounding resistance, contact voltage, step voltage, and soil resistivity, providing comprehensive testing of grounding systems.

    Q:Where can this tester be used?
    A:It is mainly used for grounding system testing in substations, power plants, lightning protection systems, and other large-scale electrical facilities.

    Q:Can it be used for large grounding grids?
    A:Yes. It is specifically designed for large grounding grid testing and is suitable for grounding systems in substations and power plants.

    Q:Can it measure contact voltage and step voltage?
    A:Yes. The tester supports contact voltage and step voltage measurements to help evaluate the safety of grounding systems.

    Q:Is it suitable for periodic maintenance of grounding systems?
    A:Yes. Power utilities, power plants, and electrical testing companies can use it for periodic inspection and preventive maintenance of grounding systems.









    Das könnte Ihnen auch gefallen

    • Haben Sie Fragen!

      Zögern Sie nicht, uns jederzeit zu kontaktieren
      Kontaktiere uns
    • Besuchen Sie uns

      Gebäude 6, Optics Valley Optical-Mechanical Industrial Park, 84 Gaoxin 5 Road,
      East Lake New Technology Development Zone, Stadt Wuhan, Provinz Hubei, China

    • Schreiben Sie uns eine E-Mail

      qiao@hvtest.cc

    • Rufen Sie uns an

      +86-15871365102