qiao@hvtest.cc15871365102
  • UHV(V) Lightning Impulse Voltage Generator System

    Das UHV(V)-Blitzimpuls-Spannungsgeneratorsystem besteht hauptsächlich aus einem Blitzimpuls-Spannungsgenerator, einem Blitzimpuls-Messschaltschrank usw. Es wird für den Blitzimpuls-Vollwellen-, Schnittwellen- und Betriebswellen-Spannungstest für GIS, Isolatoren, Transformatoren usw. verwendet. Durchführung, HV-Schaltanlage, Leistungsschalter, Lastschalter, Ringnetzwerkschrank.

     

    It has the features:

     

    1.Adopting PLC technology and using two core optical fibers to transmit control commands and feedback device status, thereby avoiding electromagnetic interference and improving the safety of the control system and computer.

    2.The control function has manual, fully automatic, and program control functions, and each level of function is relatively independent to ensure the reliability of the system.

    3.Adopting thyristor voltage regulation method and equipped with a charging voltage feedback measurement system.

    4.The ignition ball gap and cutoff ball gap distance can be manually and fully automatically adjusted, and displayed on the LCD panel.

    5.A cutoff trigger pulse with adjustable time delay and a feedback system with generator ignition trigger.

    6.By using a function controlled constant current charging method, the stability of the charging voltage can reach 0.5%.

    7.The LCD panel can indicate the charging voltage and charging process of the impact generator, with an accuracy of 1%.

    8.The charging voltage and time can be directly input from the LCD panel.

    9.Equipped with abnormal charging protection function, capable of fully automatic or manual triggering of ignition pulses

    10.Indication of the working status of the impact generator, such as spontaneous combustion, not triggered, abnormal charging, stable charging, etc.

    11.The grounding and grounding release control of the equipment body and charging part.

    12.The charging voltage polarity can be automatically switched through the buttons on the controller

    13.Charging process with automatic or manual control of charging voltage

    14.Can automatically or manually sound the alarm bell

    15.Equipped with automatic protection for overcurrent and overvoltageØ

    16.Isolation filter shielding design

    Das könnte Ihnen auch gefallen

    • Haben Sie Fragen!

      Zögern Sie nicht, uns jederzeit zu kontaktieren
      Kontaktiere uns
    • Besuchen Sie uns

      Gebäude 6, Optics Valley Optical-Mechanical Industrial Park, 84 Gaoxin 5 Road,
      East Lake New Technology Development Zone, Stadt Wuhan, Provinz Hubei, China

    • Schreiben Sie uns eine E-Mail

      qiao@hvtest.cc

    • Rufen Sie uns an

      +86-15871365102