Characteristics and Applications of VLF High Voltage Generator
2025-03-18The very low frequency high voltage generator under the UHV power can help many power workers conduct various power tests more conveniently.Very low frequency high-voltage generators are generally used for voltage withstand tests of power cables and can also be used for insulation voltage withstand tests of large power transformers.Its characteristic is that it has no damage to the tested cable, and can also test cables that have begun to age but are still usable. It is a non-destructive voltage testing method.This test more accurately determines the connection errors of new and repaired cables at their joints and ends than DC high voltage testing.Industry standard "Test method for very low frequency (0.1Hz) voltage of xLPE insulated power cables below 35kV". According to the requirements of this industry standard, the testing procedure is as follows:All electrical equipment connected to the test product should be separated from the test cable, and the test equipment (very low frequenc
MEHR -
Design requirements for microcomputer relay protection devices
2025-03-18The relay protection tester under UHV power can help many power workers conduct various power tests more conveniently.Design requirements for microcomputer relay protection device:(1) The microcomputer relay protection device should have the ability to resist electromagnetic interference.(2) The microcomputer relay protection device should be equipped with online automatic detection. In the microcomputer relay protection device, when any damage occurs to the microcomputer part, an abnormal device message should be sent out and the corresponding protection should be automatically locked when necessary. But the design of the outlet circuit of the protective device should be simple, and it is not advisable to add components that may reduce safety in the circuit to achieve complete self inspection of the outlet circuit.(3) All output terminals of the microcomputer relay protection device should not be electrically connected to its weak current system.(4) The microcomputer relay protection
MEHR -
Main functions of circuit breaker characteristic tester
2025-03-17The circuit breaker tester under UHV power can help many power workers conduct various power tests more conveniently.According to the GB10963-1999 "Overcurrent Protection Circuit Breakers for Household and Similar Places" standard, conduct a trip characteristic test on the circuit breaker.1) Time current characteristic testFrom the cold state, the circuit breaker should not trip when powered with a current of 1.13In (contracted non trip current) until the agreed time. Then, within 5 seconds, the current should be steadily increased to 1.45 In (the agreed tripping current), and the circuit breaker should trip within the agreed time.Starting from the cold state, the current of the circuit breaker should be 2.55In, and the disconnection time should be greater than 1s. The disconnection time of circuit breakers with rated current less than or equal to 63A should be less than 60s, and for open circuits with rated current greater than 63A. The disconnection time should be less than 120 secon
MEHR -
Precautions for Transformer Winding Deformation Testing Machine
2025-03-14The UHV power professional production transformer winding deformation tester can help many power workers conduct various power tests more conveniently.Precautions for determining transformer winding deformation:a) The necessary conditions for transformer winding deformation are outlet short circuit, near-field short circuit, multiple overcurrent actions, and collisions during transportation;b) The frequency response curves of the low-frequency part (tens of kHz) can generally overlap well, otherwise it is suspected that the test wiring has poor contact;c) Generally speaking, transformers of 35kV and below (including those undergoing factory renovation) may have poor frequency response characteristics, and original data comparison should be retained during handover;d) The measured frequency response curve is generally between+20 and -80 dB. If exceeded, check whether the test circuit has poor contact or disconnection;e) When the angle winding is tested separately, the three-phase freque
MEHR -
Product features of transformer no-load loss tester
2025-03-14The UHV power professional production transformer capacity tester can help many power workers conduct various power tests more conveniently.1. It can measure the no-load current, no-load loss, impedance voltage, load loss, and zero sequence impedance of various transformers.2. It can automatically perform waveform distortion correction, temperature correction (providing simple temperature correction and additional loss correction respectively), voltage correction (no-load testing under non rated voltage), and current correction (short-circuit testing under non rated current conditions), which is very suitable for units with slightly larger capacity transformers that do not have short-circuit testing conditions3. It can measure three-phase voltage, three-phase current, average voltage, average current, two-phase active power (due to the two-phase meter method, only the power of phases A and C are displayed here), total power4. It can measure the 2-42nd harmonic content of each phase vol
MEHR -
Analysis of the advantages and disadvantages of DC and AC in cable withstand voltage testing
2025-03-13The AC resonant test set under UHV power can help many power workers conduct various power tests more conveniently.The two methods of cable withstand voltage testing, AC and DC, each have their own advantages and disadvantages for reference.1、 Cable DC withstand voltage test1. Advantages:If the cable adopts DC withstand voltage method, the leakage current will be very small, and the power of the DC high-voltage generator is also relatively small, so the equipment is lightweight and easy to carry;2. Disadvantages:When using direct current for cable withstand voltage, parasitic charges are easily generated, and the higher the voltage, the greater the charge, and discharge cannot solve the problem at all. Practice has proven that there are many good local insulation problems in cables when conducting DC withstand voltage tests on 35kV and above. At present, AC testing is mandatory for cables of 35kV and above. The DC withstand voltage test is destructive to the cable, and the cable should
MEHR -
Procedure for using grounding resistance tester
2025-03-12The grounding resistance tester under UHV power can help many power workers conduct various power tests more conveniently.1、 Preparation work1. Carefully read the user manual of the grounding resistance tester, familiarize yourself with the structure, performance, and operation methods of the grounding resistance tester.2. All measuring tools and accessories must be prepared, instruments and grounding probes must be wiped, especially grounding probes, and dirt and rust affecting conductivity on their surfaces must be removed.3. Disconnect the connection point between the grounding main line and the grounding body, or the connection point of all grounding branches on the grounding main line, so that the grounding body is disconnected from any connection and becomes an independent body.Preparation work is an important task before measurement. If these preparations are not made, it is likely that the measurement will not proceed smoothly or the measurement results will not be accurate eno
MEHR -
Explanation of Common Terminology for High Voltage Test Equipment
2025-03-12The DC high voltage generator under the UHV power can help many power workers conduct various power tests more conveniently.In order to help you have a more comprehensive understanding of high-voltage testing, manufacturers of high-voltage testing equipment have organized explanations of commonly used terms for high-voltage testing equipment, hoping to be helpful to you.1. Dielectric: also known as insulating material, abbreviated as insulation, is one of the most widely used materials in electrical engineering.2. Insulation resistance: The resistance corresponding to the leakage current flowing through a dielectric after applying a DC voltage for a certain period of time.3. Absorption ratio: The ratio of the insulation resistance value at 60 seconds to the insulation resistance value at 15 seconds in the same experiment.4. Polarization index: The ratio of the insulation resistance value at 10 minutes to the insulation resistance value at 1 minute in the same experiment.5. Dielectric l
MEHR -
How to choose a grounding resistance tester
2025-03-11The grounding resistance tester under UHV power can help many power workers conduct various power tests more conveniently.The grounding resistance tester is a commonly used instrument for measuring grounding resistance, and is also an indispensable tool for electrical safety inspection and completion acceptance of grounding engineering. With the rapid development of computer technology, grounding resistance testers have penetrated into many microprocessor technologies, and their measurement functions, content, and accuracy are unparalleled. The grounding resistance tester adopts a new clamp method, which can directly measure online without the need for pile driving and wiring. Controlled by a microprocessor, it automatically detects the connection status of each interface and the interference voltage and frequency of the grounding grid, with unique numerical retention and intelligent prompt functions.Selection of grounding resistance tester:1. At present, intelligent grounding resistan
MEHR -
Series resonant overvoltage and its conditional characteristics
2025-03-11The series resonance under UHV power can help many power workers conduct various power tests more conveniently.In the power system, some inductive and capacitive components can form various oscillation circuits during system operation or failure. Under certain energy sources, series resonance phenomena can occur, leading to severe overvoltage in certain components of the system.classification(1) The linear resonant overvoltage resonant circuit is composed of inductive elements without iron cores (such as the inductance of transmission lines and leakage inductance of transformers) or inductive elements with iron cores that have excitation characteristics close to linearity (such as arc suppression coils) and capacitive elements in the system.(2) The ferromagnetic resonance overvoltage resonance circuit is composed of inductive components with iron cores (such as no-load transformers and voltage transformers) and capacitive components of the system. Due to the saturation phenomenon of ir
MEHR -
Characteristics of Transformer Capacity Characteristics Tester
2025-03-10The UHV power professional production transformer capacity tester can help many power workers conduct various power tests more conveniently.1. Can accurately measure the capacity of various distribution transformers, passive measurement, convenient and accurate.2. Equipped with an internal power supply, it automatically generates a three-phase high-power test power supply.3. It can measure the no-load current, no-load loss, short-circuit voltage, and short-circuit loss of various transformers.4. It can automatically perform waveform distortion correction, temperature correction, voltage correction, and current correction (short-circuit testing under non rated current conditions). Operators only need to input calibration indicators according to the transformer type to automatically calculate the corrected results. It is very suitable for units without short-circuit testing conditions for slightly larger transformers.5. Voltage circuit width limit: The maximum voltage can be measured up
MEHR -
Explain the working principle and application of DC resistance tester
2025-03-07The DC resistance tester under UHV power can help many power workers conduct various power tests more conveniently.The measurement of DC resistance in transformer windings is an important part of its daily testing. By measuring the DC resistance, it is possible to check the quality of the coil, whether the contact position of the tap changer is good, whether the coil or lead is broken, whether the parallel branch is correct, and whether there is a short circuit phenomenon, which is an important data for determining the short-circuit loss. Therefore, this experiment should be conducted after the handover, pre testing, major repair, and replacement of the tap changer. In recent years, with the continuous increase of power system capacity, transformer capacity has also been increasing. The larger the transformer capacity, the higher the voltage level, and the greater the ratio of inductance to resistance. Therefore, the stability time of a large transformer winding DC circuit may be sever
MEHR -
Precautions for using high-frequency DC high voltage generator
2025-03-07The DC high-voltage generator under the UHV power company can help many power workers conduct various power tests more conveniently.1. Personnel using high-frequency DC high voltage generators must have a professional with a High Voltage Test Certificate.2. When using this instrument, users must comply with the provisions of 168 "Power Safety Regulations" and install two obvious disconnection points before entering the testing instrument with the working power supply. When replacing samples and wiring, it is necessary to clearly disconnect the two power disconnection points.3. Before testing, please check if all test wiring, control boxes, multiplier tubes, and grounding wires of the tested product are connected correctly. The ground wire of the test circuit should be grounded at a single point according to the requirements of this instrument manual.4. Special discharge resistor rod is used for discharging large capacitor samples. Do not immediately come into contact with the test obje
MEHR -
Operation method of closed flash point tester
2025-03-06The closed flash point tester under UHV power can help many power workers conduct various power tests more conveniently.Usage and operation steps:1. Instrument installation:(1) Open the instrument packaging and check for damage;(2) Check the instrument model and accessories according to the packing list;(3) Debugging can only be carried out after the instrument is checked for accuracy.2. Power on preparation:(1) Insert the power cord into an AC220V three pin socket;(2) Clean the test oil cup with petroleum ether.3. Test program:(1) Turn on the power switch and display the screen;(2) Press the enter system (play) button to display the screen;(3) Press the (self-test) button to enter the self-test interface; Press the (arm lift) button, and the arm will automatically stop when it reaches its maximum height.(4) Put the test oil sample into a cleaned oil cup to the specified mark, place it in the heating bath cover, and then press the (lower arm) button. When the lower arm descends
MEHR -
Tägliche Wartung des Teilentladungsprüfers
2025-03-05Die spezialisierte Fertigung von Teilentladungsmessgeräten für Höchstspannungsanlagen erleichtert vielen Energiefachkräften die Durchführung verschiedener Leistungsprüfungen. Teilentladungsdetektoren werden in zahlreichen Branchen eingesetzt, wobei sich Häufigkeit und Einsatzumgebung je nach Branche unterscheiden. Um genaue Messergebnisse zu gewährleisten und die Lebensdauer des Detektors zu verlängern, ist eine regelmäßige Wartung erforderlich. Im Folgenden werden die täglichen Wartungsarbeiten an Teilentladungsdetektoren erläutert. 1. Teilentladungsdetektoren müssen vor Feuchtigkeit geschützt werden, insbesondere in Gebieten mit hoher Luftfeuchtigkeit. Das Gerät sollte trocken gelagert werden. Bei längerer Nichtbenutzung sollte es zweimal monatlich für zwei Stunden eingeschaltet werden, um die Feuchtigkeit zu entziehen. Bei Lagerung an einem Ort ohne korrosive Gase und Substanzen sollte die Luftfeuchtigkeit 85 % nicht überschreiten. 2. Teilentladungsmessgeräte können in vielen Situationen im Freien eingesetzt werden.
MEHR -
Wie funktioniert der Funktionstester für Hochspannungsschalter?
2025-03-05Der Leistungsschaltertester für Höchstspannungsanlagen erleichtert vielen Energiefachkräften die Durchführung verschiedener Leistungsprüfungen. Die Hauptfunktion des Hochspannungsschalter-Charakteristiktesters besteht in der Messung von Parametern wie Schaltpunkt, Schließzeit, Schaltverhalten und Schaltgeschwindigkeit. Die wichtigsten Testzeitpunkte sind die Schließ- und Öffnungszeit. Bei der Verwendung müssen die entsprechenden Verfahrensvorschriften unbedingt eingehalten werden. Heute werden die Eigenschaften und die Bedienungsschritte des Hochspannungsschalter-Testers detailliert erläutert. 1. Schließen Sie die Stromversorgung des Hochspannungsschalter-Charakteristiktesters an. Der Cursor sollte nun auf die dynamische Funktion zeigen. Drücken Sie die Bestätigungstaste, um in den Prüfmodus zu wechseln. 2. Parameter einstellen. Nach Abschluss des ersten Schritts müssen die Parameter eingestellt werden. Um die Schalterparameter anzuzeigen oder zu ändern, drücken Sie eine Taste, um in den Parametereinstellungsmodus zu gelangen. Sie können Vakuum- oder Nicht-Vakuum-Schalter testen.
MEHR -
Wartungstechniken für Gleichstrom-Widerstandsmessgeräte für Transformatoren
2025-03-04Der Gleichstrom-Widerstandsmesser unter Höchstspannung erleichtert vielen Energiefachkräften die Durchführung verschiedener Leistungsprüfungen. Fehlfunktionen von Leistungstransformatoren können zu schweren Sicherheitsunfällen führen. Regelmäßige Wartung und Instandhaltung gewährleisten den sicheren und reibungslosen Betrieb von Transformatoren. Heute stellen wir Ihnen die Techniken der täglichen Transformatorenwartung vor. 1. Verstärkte tägliche Wartung und regelmäßige Inspektionen: Gemäß der Arbeitsteilung im Management in Taiwan sind neben der regulären Transformatorenwartung auch die täglichen Wartungsarbeiten und die Aufgabenverteilung für das Management verpflichtend. Die wichtigsten Inspektionsinhalte umfassen: 1. Sichtprüfung. Die Hauptinspektion dient der Überprüfung auf Ölleckagen, Rauchentwicklung oder Emissionen an Bauteilen. Lose Schweißnähte am Transformatorengehäuse oder instabile Gummidichtungen können zu Leckagen führen. Bei zu niedrigem Ölstand geht der Isolationsschutz verloren, was zu Entladungen zwischen den leitfähigen Teilen oder zwischen den Leitern führen kann.
MEHR -
Vor-Ort-Prüfprogramm für digitale Erdungswiderstandsmessgeräte
2025-03-04Das Erdungswiderstandsmessgerät für Höchstspannungsanlagen erleichtert vielen Energiefachkräften die Durchführung verschiedener Prüfungen. Digitale Erdungswiderstandsmessgeräte werden in Bereichen wie Energieversorgung, Post und Telekommunikation, Straßenbau, Kommunikation, Bergbau usw. eingesetzt, um den Erdungswiderstand und den supraleitenden Widerstand von Geräten mit niedrigen Widerstandswerten zu messen. Darüber hinaus können sie auch den spezifischen Erdungswiderstand und die Erdungsspannung messen. Die spezifischen Messschritte mit dem digitalen Erdungswiderstandsmessgerät sind wie folgt: 1. Zuerst den Erdungswiderstand messen: Entlang der zu prüfenden Erdungselektrode E (C2, P2) werden die Potentialsonde P1 und die Stromsonde C1 in einer geraden Linie im Abstand von 20 Metern angeordnet, wobei sich die Potentialsonde in der Mitte zwischen E und C befindet. Die Sonde wird gegebenenfalls in die Erde gesteckt. Die Erdungswiderstandsanschlüsse E (C2, P2), P1 und C1 werden mithilfe eines speziellen Leiters mit der Sondenposition verbunden. Das Gerät wird eingeschaltet.
MEHR -
Wie reinigt man den Ölbecher des Spannungsfestigkeitsprüfgeräts für Isolieröl?
2025-03-03Das Prüfgerät für die dielektrische Festigkeit von Isolieröl unter Höchstspannung erleichtert vielen Energiefachkräften die Durchführung verschiedener Leistungsprüfungen. Im Arbeitsalltag von Energiefachkräften ist es häufig erforderlich, das Isolieröl von Leistungstransformatoren und dessen Spannungsfestigkeit zu messen. Daher ist ein solches Prüfgerät unerlässlich. Nach Gebrauch muss der Ölbehälter gründlich gereinigt werden, um ihn für den nächsten Einsatz vorzubereiten. Eine unzureichende Reinigung beeinträchtigt die Messgenauigkeit. Wie reinigt man den Ölbehälter des Prüfgeräts für dielektrische Festigkeit und Spannungsfestigkeit, die speziell Isolieröl benötigen? Dieser Artikel bietet Ihnen eine kurze Anleitung. Wischen Sie die Elektrodenoberfläche und den Elektrodenstab wiederholt mit einem sauberen Seidentuch ab. Stellen Sie den Elektrodenabstand mit einer Standardlehre ein. Waschen Sie die Elektroden dreimal mit Petrolether (verwenden Sie keine anderen organischen Lösungsmittel). Gehen Sie dabei jedes Mal wie folgt vor: Geben Sie Petrolether in einen Behälter mit Öl.
MEHR -
Lösung zur Messung des Transformatorüberwiderstands mit einem Gleichstrom-Widerstandsmessgerät
2025-02-28Der Gleichstrom-Widerstandsmesser für Höchstspannungsanlagen erleichtert vielen Energietechnikern die Durchführung verschiedener Prüfungen. Die Gleichstrom-Widerstandsmessung dient der Überprüfung der Qualität von Wicklungsschweißungen und Windungsschlüssen, der korrekten und korrekten Position des Stufenschalters sowie der Integrität der Zuleitungen und der Parallelwicklung. Die Gleichstrom-Widerstandsmessung ist nicht nur nach Transformatorüberholungen, Vorprüfungen und Änderungen der Stufenschalterposition unerlässlich, sondern auch nach Störungen. Die Messung des Gleichstrom-Widerstands von Transformatorwicklungen und Hochleistungsinduktivitäten mit herkömmlichen Methoden wie der Brücken- und der Spannungsfallmethode ist zeitaufwendig und mühsam. Um dies zu verbessern, die Messzeit zu verkürzen und die Arbeitsbelastung der Prüfer zu reduzieren, bietet die Höchstspannungstechnik eine Lösung.
MEHR